BENEFITS
APPLICATION/SIZING
INSTALLATION TIPS
OPERATION TIPS
4C Cartridge
Delivers premium quality water for cold cup vending applications
4C Replacement Cartridge:
EV9600-00 (1-pack)
EV9601-00 (6-pack)
4C Replacement Cartridge:
EV9600-00 (1-pack)
EV9601-00 (6-pack)
Provides clear, fresh, premium quality ingredient
water for great tasting cold beverages
Everpure's unique filter blend using activated
carbon reduces chlorine taste and odor and other
offensive contaminants
Precoat submicron technology reduces dirt and
particles as small as 1/2 micron in size
Reduces possible health contaminants such as
asbestos fibers and Cryptosporidium and Giardia
cysts
Does not remove fluoride
Sanitary cartridge replacement is simple, quick
and clean. Internal filter parts are never exposed
to handling or contamination
NSF Certified under NSF/ANSI Standards 42
and 53
Never use saddle valve for connection
Use 3/8” water line
Install vertically with cartridge hanging down
Allow 2-1/2” clearance below the cartridge for
easy cartridge replacement
Flush 4C cartridge by running water through
filter for three minutes at full flow
Change cartridges on a regular 6 month
preventative maintenance program
Change cartridges when capacity is reached or
when pressure falls below 10 psi
Service flow rate must not exceed 0.5 gpm
Always flush the filter cartridge at time of
installation and cartridge change
For cold cup vending machine applications
Capacity: 3,000 gallons (11,355L)
EV9600-00